Model No : SU-016 1. Product Features and Specifications 1.1. Features 1.2. Electrical Specifications 2. Mechanical Dimensions  3. Mounting Instructions  4. Wiring Instructions 4.1. Pigtail color code 4.2. Configuration 1 : Standalone Spintly Reader (Entry only) 4.3. Configuration 2 : Spintly Entry + Exit reader 4.4. Configuration 3 : Spintly Reader with OSDP Controller 4.5. Configuration 4 : Spintly Reader with Wiegand Controller

Model No : SU-016


Spintly UNO-WO Reader with it’s elegant design provides seamless user experience that allows users to unlock doors with their smartphones.


1. Product Features and Specifications


1.1. Features

  • BLE Mesh connectivity to Gateway
  • Wide Input operating voltage range
  • Retrofit with legacy controllers over Wiegand or OSDP
  • Tamper detection
  • Cloud-based access management
  • Adjustable operational distance for Mobile credential access
  • Over-the-air firmware update support
     

 

1.2. Electrical Specifications

  • Power source: 12V/24V DC Input
  • Power consumption: 2.4W max at 12V

 

2. Mechanical Dimensions 
 

 

 

3. Mounting Instructions 

Step 1. Pre-drill the mounting locations using Drill Template provided in the box.
Then mount the back plate on the wall with the help of wall plugs and screws (4 qty) as shown below. 

 

Step 2.  Before proceeding with wiring, toggle the Interface Switch to either W (Wiegand) or O (OSDP) position based on the selected configuration (Refer Wiring Instructions – section 4. Applicable to configuration 3 or 4 based on the switch position)

 


Step 3. Strip and connect the wires as per the pigtail color code (refer Fig 4.1.1) and connection diagram (refer Fig 4.2.1) under Wiring Instructions - Section 4.

 

 

Step 4. Once the connection is done, pass the pigtail through the back plate opening

 

 

Step 5. Mount the reader on the back plate and secure it using M3 x 8mm screws (2qty)

 

 

 

 

4. Wiring Instructions

4.1. Pigtail color code

UNO-WO reader is equipped with a 10 core pigtail required during the connection process. The table below describes the signal names along with their corresponding color code.

The reader supports various modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below.

 

4.2. Configuration 1 : Standalone Spintly Reader (Entry only)

 

  • Short VIN wire to COMMON wire of Entry Reader
  • Connect the locking mechanism (Strike lock or Magnetic lock) to NC (in case of mag lock) wire of Entry Reader
  • The sensor inputs:
    • Door Sensor - Connect to the Entry reader
    • REX - Connect to the Entry reader 

 

4.3. Configuration 2 : Spintly Entry + Exit reader

 

  • In this mode, both the entry and exit Spintly readers will share the same power lines. Connect together the VIN wires of both the readers. Similarly, for GND wires (ground)
  • Connect OSDP wires - Green and White to respective wires of exit reader (as shown in above Fig 4.3.1)
  • Short VIN wire to COMMON wire of Exit Reader
  • Connect the locking mechanism (Strike lock or Magnetic lock) to NC (in case of mag lock) wire of Exit Reader
  • The Door sensor should be connected to Exit reader

 

4.4. Configuration 3 : Spintly Reader with OSDP Controller

  • Make sure the interface switch on reader is toggled to “O” (OSDP) position as instructed previously.  Refer to section 3 – step 2. (for Model No : SU-016)
  • Below mentioned 4 wires should be connected from Reader to the respective terminal of Controller:
    • Power wires — VIN and GND
    • Communication wires — Connect RS485 A and RS485 B (refer the color code shown in the above table) to the A and B terminal of the controller respectively. Refer controller manual for more details.
  • Connect the locking mechanism and sensor inputs (Door sensor and REX) to controller

 

 

4.5. Configuration 4 : Spintly Reader with Wiegand Controller

  • Make sure the interface switch is toggled to “W” (Wiegand) position as instructed previously. Refer to section 3 - step 2. (for Model No : SU-016)
  • Below mentioned 5 wires should be connected from Reader to the respective terminal of Wiegand controller:
    • Power wires — VIN and GND
    • Communication wires — DATA0 (D0), DATA1 (D1), and GLED (refer the color code shown in above table) to the respective terminals of Wiegand controller.
  • Connect the locking mechanism and sensor inputs (Door sensor and REX) to controller
copy wireless

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Spintly UNO
  • Setup for Google Workspace SCIM with Spintly
  • Setup for Microsoft Azure AD SCIM with Spintly
Spintly

Industries

  • Multifamily / Residential
  • Co-Working
  • Education
  • Healthcare
  • Hospitality
  • Manufacturing
  • Fitness & Wellness

Solutions

  • Access Control
  • Visitor Management
  • Tenant Management
  • Time & Attendance Management

About

  • About Us
  • Partners
  • FAQ
  • Privacy Policy
  • Terms & Conditions

Resources

  • Case Studies
  • Blogs
  • Whitepapers
  • Webinars
  • Press
  • Data Sheets

Contact Us

  • Sales: sales@spintly.com
  • Tech Support: support@spintly.com
  • Get a Quote
© 2024 Spintly. All Rights Reserved. | 691 S Milpitas Blvd, Ste 217 Milpitas, CA 95035
Expand