Model No : SQR-021
Spintly ZEON offers a complete solution for users and visitors by blending QR / Barcode scanning with BLE and NFC access. This ensures easy operation across all levels.
1. Product Features and Specifications
1.1. Features
- Wireless BLE Mesh Networking
- Easy to Install and Set-up
- QR based access
- Cloud-based platform
- Smartphone-based access
- Card-based access
1.2. Electrical Specifications
- Power source: 12V / 24V DC Input
- Power consumption: 2.4W max at 12V
2. Mechanical Dimensions
3. Mounting Instructions
Step 1. Pre-drill the mounting locations using Drill Template provided in the box.
Then mount the back plate on the wall with the help of wall plugs and screws (ISO #6, 25mmL, PAN+, 2 qty) as shown below.
Step 2. Strip and connect the wires as per the pigtail color code (refer Fig 4.1.1) and connection diagram under Wiring Instructions - Section 4.
Step 3. Once the connection is done, pass the pigtail through the back plate opening
Step 4. Mount the reader on the back plate (align in the backplate notch) as shown in the image below
Step 5. Secure the reader using M3 x 8mm screws (1 qty) as shown in image below
4. Wiring Instructions
4.1. Pigtail color code
QR reader is equipped with a 8 core pigtail required during the connection process. The table below describes the signal names along with their corresponding color code.
The reader supports various modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below.
4.2. Configuration 1 : Standalone Spintly Reader
Installation type : Entry Reader and REX
- Short VIN wire to COMMON wire of Entry Reader
4.3. Configuration 2 : Spintly Entry with Exit reader
Installation type : Entry-Exit (OSDP disabled)
- In this mode, both the entry and exit Spintly readers will share the same power lines. Connect together the VIN wires of both the readers. Similarly for GND wires (ground).
- Short VIN wire to COMMON wire of Entry Reader
- Short NC (in case of mag lock) wire of Entry Reader to COMMON wire of Exit Reader
- Connect the locking mechanism (Strike lock or Magnetic lock) to NC (in case of mag lock) wire of Exit Reader
-
The sensor inputs (REX and Door sensor) should be connected to Exit reader