Spintly UNO-W
Table of Contents
Spintly UNO-W Reader with it’s elegant design provides seamless user experience that allows users to unlock doors with their smartphones.
1. Product Features and Specifications
1.1. Features
- Wireless BLE Mesh Networking
- Easy to Install and Set-up
- Works without Internet
- Cloud based platform
- Smartphone based access
- Card based access
- Retrofit with legacy controllers over Wiegand
1.2. Electrical Specifications
- Power source: 12V/24V DC Input
- Power consumption: 2.4W max at 12V
2. Mechanical Dimensions
3. Mounting Instructions
Step 1. Pre-drill the mounting locations using Drill Template provided in the box.Pre-drill the mounting locations using Drill Template provided in the box.
Then mount the back plate on the wall with the help of wall plugs and screws (4 qty) as shown below.
Step 2. Strip and connect the wires as per the pigtail color code and connection diagram. Refer Fig 4.2.1 under Wiring Instructions - Section 4.
Step 3. Once the connection is done, pass the pigtail through the back plate opening
Step 4. Mount the reader on the back plate and secure it using M3 x 8mm screws (2qty)
4. Wiring Instructions
4.1. Pigtail color code
UNO-W reader is equipped with a 10 core pigtail required during the connection process. The table below describes the signal names along with their corresponding color code.
The reader supports various modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below.
4.2. Configuration 1 : Standalone Spintly Reader (Entry only)
- Short VIN wire to COMMON wire of Entry Reader
- Connect the locking mechanism (Strike lock or Magnetic lock) to NC (in case of mag lock) wire of Entry Reader
-
The sensor inputs:
- Door Sensor - Connect to the Entry reader
- REX - Connect to the Entry reader
4.3. Configuration 2 : Spintly Entry with Exit reader
- In this mode, both the entry and exit Spintly readers will share the same power lines. Connect together the VIN wires of both the readers. Similarly, for GND wires (ground).
- Short VIN wire to COMMON wire of Entry Reader
- Short NC (in case of mag lock) wire of Entry Reader to COMMON wire of Exit Reader
-
The sensor inputs:
- Door Sensor - To enable DOTL, please connect the door sensor to the Entry Reader (as shown in above Fig 4.3.1)
- Door break-in feature is not available under this configuration.
4.4. Configuration 3 : Spintly Reader with Wiegand Controller
-
Below mentioned 5 wires should be connected from Reader to the respective terminal of Wiegand controller
- Power wires -- VIN and GND
- Communication wires -- DATA0 (D0), DATA1 (D1), and GLED (refer the color code shown in above table) to the respective terminals of Wiegand controller
- Connect the locking mechanism and sensor inputs (Door sensor and REX) to controller