Configuration Type : Spintly Entry + Exit Reader
Note: below wirings are applicable to following readers : UNO, HALO, ZEON, 3-IN-1

Wiring Explanation for technician
-
Power Supply (SMPS / Adapter 12V DC)
- Connect VIN (RED) of Entry & Exit readers together
- Connect GND (BLACK) of Entry & Exit readers together
- Power both readers from same 12V SMPS/Adapter
-
Entry Reader Relay Wiring
- Short VIN (RED) → COM (BROWN) of Entry Reader
- This feeds power into the relay
-
Lock Wiring (Magnetic Lock)
- Short NC (PURPLE) of Entry Reader → COM (BROWN) of Exit Reader
- Use NC (PURPLE) of Exit reader for magnetic lock
- Lock + → NC (PURPLE) of Exit Reader
- Lock – → GND (BLACK)
-
Door Sensor
- Connect Door Sensor only to Entry Reader
- Required for DOTL (Door Open Too Long)
-
Limitations
- Door break-in feature NOT supported in this configuration
Important Notes
- Magnetic lock = NC only
- Both readers control the same lock
- Ensure common ground everywhere